PMS
New report History
← Back to report history

Yashwant Bodke Residence

PPR-2026-09-00181 · 01 Sep 2026, 11:52 PM
Done
EngineerPratik
Site typeVRV · General
People on site2
Activity2 Panels - Panels and sensor installation done.
Tomorrow's planPlanned for tomorrow: Commissining.
Next step date

Current project steps

22 tracked
LS Material Delivery
Done
01 Sep 2026, 11:52 PM · Pratik
Marking
Done
01 Sep 2026, 11:52 PM · Pratik
Civil Opening
Done
01 Sep 2026, 11:52 PM · Pratik
Support
Done
01 Sep 2026, 11:52 PM · Pratik
LS Pressure Testing
Done
01 Sep 2026, 11:52 PM · Pratik
IDU/ODU Pressure Testing
Done
01 Sep 2026, 11:52 PM · Pratik
1st RA Measurement Submitted by PE
Done
01 Sep 2026, 11:52 PM · Pratik
HS Material Delivery ODU
Done
01 Sep 2026, 11:52 PM · Pratik
odu unit installation
Done
02 Sep 2026, 11:38 PM · Pratik
Final Nitrogen Testing
Done
01 Sep 2026, 11:52 PM · Pratik
Copper Piping Dismental
Not required
02 Sep 2026, 11:38 PM · Pratik
Underdake Insulation
Not required
01 Sep 2026, 11:52 PM · Pratik
Drain Dismental
Not required
02 Sep 2026, 11:38 PM · Pratik
Main Ducting
Not required
01 Sep 2026, 11:52 PM · Pratik
Main Ducting Dismental
Not required
02 Sep 2026, 11:38 PM · Pratik
Fresh Air - PVC PIPE / Duct
Not required
01 Sep 2026, 11:52 PM · Pratik
Collar
Not required
01 Sep 2026, 11:52 PM · Pratik
IDU Dismental
Not required
02 Sep 2026, 11:38 PM · Pratik
ODU Dismental
Not required
02 Sep 2026, 11:38 PM · Pratik
Grill Installation
Not required
01 Sep 2026, 11:52 PM · Pratik
Fan Installation
Not required
01 Sep 2026, 11:52 PM · Pratik
Disk Valve
Not required
01 Sep 2026, 11:52 PM · Pratik

Complete visit timeline

2 visits
02 Sep 2026, 11:38 PM
Pratik · PPR-2026-09-00188
Step updates
Drain Dismental · Not requiredMain Ducting Dismental · Not requiredCopper Piping Dismental · Not requiredIDU Dismental · Not requiredODU Dismental · Not requiredodu unit installation · Done
ActivityAll indoor communication wiring done.
Main power supply wiring done.
Grill fitting done.
Outdoor pressure hold.
Vacuuming and valve break done.

Auto charging and testing work pending
Because there is 40A + 30MA LMCB
Required 25A +300MA LMCB
Even earthing is not provided.
Tomorrow's plan-
01 Sep 2026, 11:52 PM
Pratik · PPR-2026-09-00181
Step updates
LS Material Delivery · DoneMarking · DoneCivil Opening · DoneSupport · DoneLS Pressure Testing · DoneIDU/ODU Pressure Testing · Done1st RA Measurement Submitted by PE · DoneHS Material Delivery ODU · Doneodu unit installation · DoneFinal Nitrogen Testing · DoneCopper Piping Dismental · Not requiredUnderdake Insulation · Not requiredDrain Dismental · Not requiredMain Ducting · Not requiredMain Ducting Dismental · Not requiredFresh Air - PVC PIPE / Duct · Not requiredCollar · Not requiredIDU Dismental · Not requiredODU Dismental · Not requiredGrill Installation · Not requiredFan Installation · Not requiredDisk Valve · Not required
Activity2 Panels - Panels and sensor installation done.
Tomorrow's planPlanned for tomorrow: Commissining.

Photos and files

2 attachments

Report processing

done
photo save
done
01 Sep 2026, 11:53 PM
1 photo(s) uploaded
sheet write
done
01 Sep 2026, 11:53 PM
1 row(s) written
pms update
done
01 Sep 2026, 11:53 PM
PMS row stamped
pdf
done
01 Sep 2026, 11:53 PM
PDF built
email
done
01 Sep 2026, 11:57 PM
emailed
whatsapp
done
01 Sep 2026, 11:57 PM
SENT — doc media=1394938086062374